Service Manual Instruction Manual
SECTION 6 - JLG CONTROL SYSTEM
6-50 – JLG Lift – 3121171
6.15 CALIBRATING PLATFORM LEVEL
STEP 1: SETTING THE PLATFORM VALVE MINIMUMS
1. Position the Platform/Ground select switch to the
Ground position.
2. Plug the analyzer into the connector inside the Ground
control box.
3. Pull out the Emergency Stop switch and start the
engine.
4. The analyzer screen should read:
5. Use the arrow button to reach ACCESS LEVEL 2. Hit Enter.
6. Enter the Access Code, 33271.
7. Use the arrow button to reach PERSONALITIES adjust
the following personalities. Refer to the Personality
Ranges/Defaults table for proper setting values.
Basket Level Up Min
Basket Level Up Max
Basket Level Down Max
Jib Up Min
Jib Down Min
8. Recycle EMS.
STEP 2: BLEEDING THE PLATFORM VALVES
1. Position the Platform/Ground select switch to the
Ground position.