GROUND MODE:
m. LIFT UP XXX% Displays/adjusts fixed main lift up speed 0 to 100% 60
m. lift DN XXX% Displays/adjusts main lift down speed 0 to 100% 60
SWING XXX% Displays/adjusts fixed swing speed 0 to 65% 45
BASKET LVL XXX% Displays/adjusts fixed basket level speed 0 to 100% 75
BASKET ROT XXX% Displays/adjusts fixed basket rotate speed 0 to 100% 75
MAIN TELE XXX% Displays/adjusts fixed main telescope speed 0 to 100% 65
TOWER TELE XXX%
Displays/adjusts fixed tower telescope speed
Not displayed if TOWER TELE=NO
40 to 40% 40
T. LIFT UP XXX %
Displays/adjusts fixed tower lift up speed
Not displayed if TOWER LIFT=NO
40 to 40% 40
T. LIFT DN XXX%
Displays/adjusts fixed tower lift down speed
Not displayed if TOWER LIFT=NO
40 to 40% 40
JIB (U/D) XXX%
Displays/adjusts jib lift speed
Not displayed if JIB = 0
0 to 100% 60
JIB (L/R) XXX%
Displays/adjusts jib swing speed
Displayed if JIB = 2
0 to 100% 70
GEN SET/WELDER:
Engine XXXX RPM
Control generator/welder RPM. Not displayed if GEN
SET/WELDER = 0
1200-2800 1800
NOTES: Personality settings can be adjusted anywhere within the adjustment range in order to achieve optimum machine performance.
S to p w atch shou ld star t w he n th e fun c ti on is a c ti va ted. No t w ith t he co nt ro ll er or swi tc h.
U nl ess note d, fu nc t io n s pe ed s sh ould be m easur ed fr om pl at fo rm .
P la tf or m s pee d kn ob mus t be a t f ul l spe ed ( fully cl ockwi se).
A ll te st sh ould be don e wit h the oil t em p abov e 1 00 ° F (3 8° C ).
4150517-4