Service Manual Instruction Manual

SECTION 5 - HYDRAULICS
5-50 – JLG Lift – 3121171
c. The analyzer screen should read:
d. Use the arrow button to reach ACCESS LEVEL 2.
Press the ENTER key.
e. Enter the Access Code, 33271 to get into Access
Level 1 mode.
NOTE: The service mode will only be displayed on the analyzer
when in access level 1 or 0 in the ground mode and be hid-
den while in access level 2.
THE SERVICE MODE MENU WILL BE SELECTABLE AT THE TOP LEVEL OF THE
ANALYZER MENU STRUCTURE. “SERVICE MODE” WILL BE DISPLAYED ON THE
TOP LINE OF THE ANALYZER WITH THE CURRENT SUB-MENU SELECTION ON
THE BOTTOM LINE. THE SUB-MENUS WILL SCROLL WITH THE LEFT AND RIGHT
ARROW KEYS.
2. In this level, enter the "service mode" menu then scroll
left or right to "set pressure" submenu as shown below.
3. Set Pressures - allows function of selected submenu
with enable valve closed (to set pressure settings of
functions that should not/cannot not be independently
operated)
4. When the operator presses the ENTER key, the controller
will display "SET PRESSURES" on the top line and "CODE
00000" on the bottom line of the analyzer.