Service Manual Owner's manual

SECTION 7 - JLG CONTROL SYSTEM
3121222 – JLG Lift – 7-11
7.3 MACHINE PERSONALITY - ADJUSTMENT
SETTINGS
NOTE: These settings may change in order to achieve opti-
mal performance on a machine by machine basis.
NOTE: These settings may change in order to achieve opti-
mal performance on a machine by machine basis.
Table 7-3. Machine Personality Adjustment (4150472-H) -
Machines Equipped with Sevcon (1600346) Power
Module
Function Adjustment Range
1230ES
(Factory Setting)
DRIVE
ACCEL 0.1 - 5.0 (Sec) 0.8
DECEL 0.1 - 1.0 (Sec) 1.0
MINIMUM 0 - 25% 0
MAXIMUM 0 -100% 100
ELEV. MAX. 0 - 25% 18
LIFT
ACCEL 0.1 - 5.0 (Sec) 0.5
DECEL 0.1 - 1.0 (Sec) 0.1
UP MIN 0 - 50% 10
UP MAX 0 - 100% 100
DN MIN 1 - 60% 42
DN MAX 0 - 100% 61
STEER
STATIC 0 - 100% 100
DRIVE 0 - 100% 60
ACCELERATOR
FWD MIN 2.20 - 2.40 V 2.25
FWD MAX 1.00 - 1.50 V 1.20
REV MIN 2.60 - 2.80 V 2.75
REV MAX 3.50 - 4.00 V 3.80
GROUND
HORN 87 - 107 dB 107
ALARM 87 - 107 dB 87
LOAD
ACCY 0 - 200 Kg N/A
OVR DBNCE 0.0 - 5.0 Sec N/A
OVR HOLD 0.0 - 5.0 Sec N/A
Table 7-4. Machine Personality Adjustment (1001115627-
B) - Machines Equipped with ZAPI (1001092456) Power
Module
Function Adjustment Range
1230ES
(Factory Setting)
DRIVE
ACCEL 0.1 - 5.0 (Sec) 0.8
DECEL 0.1 - 1.0 (Sec) 1.0
MINIMUM 0 - 25% 0
MAXIMUM 0 -100% 100
ELEV. MAX. 0 - 30% 25
LIFT
ACCEL 0.1 - 5.0 (Sec) 0.5
DECEL 0.1 - 1.0 (Sec) 0.1
UP MIN 0 - 50% 20
UP MAX 0 - 100% 100
DN MIN 1 - 60% 45
DN MAX 0 - 100% 85
STEER
STATIC 0 - 100% 100
DRIVE 0 - 100% 60
ACCELERATOR
FWD MIN 2.20 - 2.40 V 2.23
FWD MAX 1.00 - 1.50 V 1.19
REV MIN 2.60 - 2.80 V 2.74
REV MAX 3.50 - 4.00 V 3.78
GROUND
HORN 87 - 107 dB 107
ALARM 87 - 107 dB 87
LOAD
ACCY 0 - 200 Kg 0
OVR DBNCE 0.0 - 5.0 Sec 3.0
OVR HOLD 0.0 - 5.0 Sec 5.0