Service Manual Owner's manual
SECTION 7 - JLG CONTROL SYSTEM
7-4 – JLG Lift – 3121222
ANALYZER SCREEN LAYOUT
ACCESS LEVEL:
CODE 33271
MENU:
ACCESS LEVEL 1
MENU:
PERSONALITIES
MENU:
MACHINE SETUP
MENU:
CALIBRATIONS
PERSONALITIES:
DRIVE
PERSONALITIES:
LIFT
PERSONALITIES:
GROUND
PERSONALITIES: *
LOAD
MARKET:
0=ANSI USA
TILT CUTOUT: *
0=NO
CHARGER INTRLOC*
0=DRIVE ONLY
GROUND ALARM: *
0=NOT INSTALLED
LOAD: *
0=NOT INSTALLED
ACCESS LEVEL:
CODE 00000
CALIBRATIONS:
TILT SENSOR
CALIBRATIONS: *
SET ELEV SENSOR
MODEL NUMBER:
1930ES
MODEL NUMBER:
2030ES
MODEL NUMBER:
2630ES
MODEL NUMBER:
2646ES
MARKET:
1=ANSI EXPORT
TILT CUTOUT: *
1=YES
CHARGER INTRLOC*
1=DRV&LIFT UP
GROUND ALARM: *
1=DESCENT
GROUND ALARM: *
2=MOTION
LOAD: *
1=CUTOUT PLT
PERSONALITIES:
STEER
PERSONALITIES:
ACCELERATOR
STEER:
STATIC 0-100%
STEER:
DRIVE 0-100%
ACCELERATOR:
FWD MIN 2.25V
ACCELERATOR:
FWD MAX 1.20V
ACCELERATOR:
REV MIN 2.75V
ACCELERATOR:
REV MAX 3.80V
DRIVE:
ACCEL 0.1-5.0 S
DRIVE:
DECEL 0.1-10.0 S
DRIVE:
MINIMUM 0-25%
DRIVE:
MAXIMUM 0-100%
DRIVE:
ELEV.MAX 0-25%
LIFT:
ACCEL 0.1-5.0S
GROUND:
HORN 107DB
LOAD: *
ACC'Y 0-200KG
LOAD: *
OVR DBNCE 3.0S
LOAD: *
OVR HOLD 5.0S
LEVEL VEHICLE:
YES:ENTER,NO:ESC
SET ELEV SENSOR: *
YES:ENTER,NO:ESC
LIFT:
DECEL 0.1-1.0S
LIFT:
UP MIN 0-50%
LIFT:
UP MAX 1-100%
LIFT:
UP MIN 0-60%
LIFT:
DN MAX 1-100%
LOAD: *
2=CUTOUT ALL
CALIBRATIONS: *
LOAD
LOAD: *
YES:ENTER,NO:ESC
CALIBRATIONS: *
DRIVE CUTOUT
DRIVE CUTOUT: *
YES:ENTER,NO:ESC
MARKET:
2=CSA
MARKET:
3=CE
MARKET:
4=AUSTRALIA
MARKET:
5=JAPAN
DRIVE CUTOUT:
0=NO
DRIVE CUTOUT:
1=YES
DRIVE MOTORS:
0=PEERLESS
DRIVE MOTORS:
1=ADVANCED DC
ELEV PROX: *
0=NOT INSTALLED
ELEV PROX: *
1=INSTALLED
MODEL NUMBER:
1230ES
MODEL NUMBER:
3246ES
BATT
E
R
Y
:
0=FL
O
O
D
E
D
B
A
T
T
E
R
Y
:
1
=
A
G
M
F
O
O
T
S
W
I
T
C
H
:
*
0
=
N
O
F
O
O
T
S
W
I
T
C
H
:
*
1
=
Y
E
S
SET ELEV SENSOR: *
0.10-1.20V X.XXV
UNCALED TILT:
+X.XX, +Y.YY
GROUND:
ALARM 87DB
Figure 7-1. Analyzer Menu Flow Chart - Sevcon vP1.14 - Sheet 1 of 2 - (4170032 -15)