Service Manual
SECTION 4 - CONTROL COMPONENTS
4-14 – JLG Lift – 3121228
2 Mode Select Delay (Active before timeout) 5 SEC. 1 - 60 SECONDS
2 Acceleration (Platform Lowered) 80 1 - 100
2 Deceleration (Platform Lowered) 90 1 - 100
2 Turn Acceleration (Platform Lowered) 80 1 - 100
2 Turn Deceleration (Platform Lowered) 100 1 - 100
2 Maximum Forward Speed (Platform Lowered) 100 1 - 100
2 Minimum Forward Speed (Platform Lowered) 40 1 - 100
2 Maximum Reverse Speed (Platform Lowered) 50 1 - 100
2 Minimum Reverse Speed (Platform Lowered) 20 1 - 100
2 Maximum Turn Speed (Platform Lowered) 30 1 - 100
2 Minimum Turn Speed (Platform Lowered) 15 1 - 100
2 Minimum Forward Speed (Platform Elevated) 13 1 - 100
2 Minimum Reverse Speed (Platform Elevated) 9 1 - 100
2 Minimum Turn Speed (Platform Elevated) 5 1 - 100
2 Motor Compensation 50 mOhms 0 - 500 mOhms
Table 4-1. Ground Control Module - Field Programmable Settings and Factory Preset. (10MSP)
Level-2: Ser v ice Le vel Se tt ing s On LC D Displ ay : YES = HIG H =
↑
Level-3: Ope ra tor Le vel Se tt ing s NO = L OW = ↓
LEVEL PROGRAMMABLE ITEM
FACTORY
PRESET
SETTING RANGE