Instructions / Assembly

Inspect frequently
Installer — Instruct the building owner to frequently inspect
the V-250 cannister cartridge neutrazlier and all condensate
connections. The owner must notify a qualified technician if any
problems are noticed.
Recharge as required
Follow the requirements onpage 2 for recharging or replacing
the V-250 cartridge. Follow instructions at right.
Replacement parts
Contact JJM Boiler Works, your local wholesaler or manufac-
turer’s representative for replacement parts and refill kit.
Maintenance
!
DANGER
Install all electrical wiring in accordance with the National
Electrical Code and local requirements.
Indicates a condition or hazard which will cause severe
personal injury, death or major property damage.
!
WARNING
Indicates a condition or hazard which may cause severe
personal injury, death or major property damage.
!
CAUTION
Indicates a condition or hazard which will or can cause
minor personal injury or property damage.
!
NOTICE
Indicates special attention is needed, but not directly related
to potential injury or property damage.
!
NOTICE
is unit when installed must be electrically grounded in
accordance with the requirements of the authority having
jurisdiction or , in the absence of such requirements, with
the current edition of the National Electrical Code, ANSI/
NFPA 70 and/or the Canadian Electrical Code, Part 1, CSA
C22.1, Electrical Code.
!
CAUTION
Label all wires prior to disconnection when servicing con-
trols. Wiring errors can cause improper and dangerous
operation. Verify proper operation aer servicing.
Electrical Rating: 115V | 1 Amp | 60 Watts | 1.5A
Tube Size 1/2”
Application:
The V-250 canister neutralizer is best applied to wall mounted
condensing hot water heaters, boilers, and floor mounted
furnaces. The V-250 pump combi model is best applied when
a condensate pump is needed to transfer the treated acidic con-
densate wastewater to a remote drain location. All acidic con-
densate wastewater is gravity fed from the appliance condensate
outlet port to the V-250 inlet port. The V-250 pump combi can
also be used for non acid air conditioning condensate removal.
Simple pipe to either of the spare inlet ports on the pump tank.
Vseries Acidic Condensate pH Treatment Kits –– Installation/Operation & Maintenance