During all transportation situations, never drop the module from a vehicle, house or
hands. This will damage the module.
Do not clean the glass with chemicals. Only use tap water. Make sure the module surface
temperature is cool to the touch. Cleaning modules with cool water when module surface
temp is high may result in glass breakage.
Do not disconnect any of the modules when under load.
The recommended standoff height is 15cm. If other mounting means are employed this
may affect the UL Listing.
When looking at PV modules with anti-reflection (AR) coating technology, it will be normal
to see some cells with a slight color difference at different angles.
Connector of junction box can not be contacted with oily substances, for example,
lubricant, rust inhibitor etc.
2. Installation
2.1 Installation safety
Always wear protective head gear, insulating gloves and safety shoes (with rubber soles).
Keep the PV module packed in the carton until installation.
Do not touch the PV module unnecessarily during installation. The glass surface and the
frame may be hot. There is a risk of burns and electric shock.
Do not work in rain, snow or windy conditions.
Due to the risk of electrical shock, do not perform any work if the terminals of the PV
module are wet.
Use insulated tools and do not use wet tools.
When installing PV modules, do not drop any objects (e.g., PV modules or tools).
Make sure flammable gasses are not generated or present near the installation site.
The modules are equipped with PV wiring connectors that comply with UL 6703,
Standard for Connectors for use in Photovoltaic Systems. Connectors from other
manufactures should not be mated with each other connectors:
Connector model name
Allowable mating connector model name
PV-JK03M-2
PV-JK03M-2
PV-JK03M-F/2B
PV-JK03M-M/2B
PV-KBT4-EVO2/6II-UR
PV-KST4-EVO2/6II-UR
Insert module connectors fully and correctly. An audible "click" sound should be heard.
This sounds confirms the connectors are fully seated. Check all connections.
The module leads should be securely fastened to the module frame. Wire Management
should be done in a way to avoid the connector from scratching or impacting the back
sheet of the module.