User's Manual

USR-G786-G User Manual Technical Support: h.usriot.com
Jinan USR IOT Technology Limited www.usriot.com
53
Format
Query current parameter
AT+CSQ{CR} or AT+CSQ?{CR}
{CR}{LF}+CSQ: rssi {CR}{LF}
Parameter
rssi Received signal strength information.
Figure 2 Mapping relation
Number
Implication
0
Less than -113 dBm
1
-111 dBm
2....31
-109... -53
dBm
99
Unknown or unmeasured
7.2.11. AT+SYSINFO
FunctionQuery module ’s network information
Format:
Query current parameter:
AT+SYSINFO{CR} or AT+SYSINFO?{CR}
{CR}{LF}+SYSINFO: state,srv_domain ,roam_status,sys_mode,sim_state{CR}{LF}
Parameter
statecurrent network status
Figure 3 Sever status list
Number
Implication
0
No service
1
Restricted service
2
Network
service
3
Restricted regional services
4
Power saving state
srv_domainbusiness domain
Figure 4 Business domain list
Number
Implication
0
No service
1
Only CS serv
ice
2
Only PS serv
ice
3
PS+CS service
4
CS,PS is not registered and is in the search state
roam_status Roaming state
0 Non-roaming state
1 Roaming state
sys_mode System mode
Figure 5 System mode list
Number
Implication
0
No service