6.2. Heartbeat Package
In network transparent mode, user can send the heartbeat package from the module to meet specific
requirements.
Heartbeat package can be sent to the network or serial port device . The main purpose of sending to the
network is to keep the connection stable and reliable, to ensure the normal connection of the module, and at
the same time, to let the server know the online status of the module.
In the application of fixed query commands sent by the server to the device, in order to reduce
communication traffic, user can choose to send heartbeat package (query commands) to the serial device
instead of sending query commands from the server, so as to save traffic and respond faster.
1 Set by software:
1. Open the dedicated setup software. Set the Serial port parameters according to the serial device and