Hold time (Unit: s)
Duration of the DO action, only valid in “High” and
“Low” of the alert triggered action. 0 means until the
next action, and other values represent the duration
of the DO action (0~255s can be set).
0
Low level width(Units: s)
Valid when the alert triggered action is “Pulse”, the
low level duration of this DO action can be set to
0~30000ms.
1000
High level width(Unit: s)
Valid when the alert triggered action is “Pulse”, the
high level duration of this DO action can be set to
0~30000ms.
1000
Alert source
DI1 or DI2 which triggers the action of this DO.
DI1
Note: The maximum voltage of DO is 36V, overcurrent protection is 300mA.
3.7. User-defined Indicator
Users can define the “USR” indicator according to the requirements.
Item
Description
Default
Enable
Enable/Disable
Disable
Event
SOCKA~Dpptpl2tpgreopenvpnipsec
SOCKA
Note:
SOCK: The light will be on when socket connection is established.
VPN: The light will be on when the VPN connection is established, only valid in Client mode(IPSEC).
TCPS: On when connecting to the clients.
TCPC/HTTPD: On when connecting to the server.
UDPC/UDPS: On when the socket connection is established.