Test Report
Number
SHAH01178957
Tests Conducted
Page 3 of 6
Intertek Testing Services Ltd., Shanghai
上海天祥质量技术服务有限公司
Block B, Jinling Business Square, No.801 YiShan
Road, Shanghai, China. 200233
上海市宜山路 801 号金陵商务广场 B 200233
Tel: +86 21 6120 6060
Fax: +86 21 6127 9708
www.intertek.com
www.intertek.com.cn
2 Cadmium (Cd) content
With reference to methods EN 1122 (Method B)/ IEC 62321:2008/ ISO 11885:2007, acid digestion method was used and
total Cadmium content was determined by Inductively Coupled Argon Plasma Spectrometry.
Tested component
Result in %
(1) ND
(2+3) ND
(4+6) ND
(5) ND
Requirement
Category Limit (%)
Paints with codes [3208] and [3209] 0.01
Paints with codes [3208] [3209] with a zinc content exceeding
10 % by weight of the paint
0.1
Painted article 0.1
Plastic 0.01
Metal parts of jewellery & hair accessories 0.01
RemarkND = not Detected (<0.0005%)
Tested ComponentsSee component list in the last section of this report.
Date Sample ReceivedDec.19, 2019
Testing PeriodDec.19, 2019 to Dec.23, 2019
******************************************************************************************************************************************************