User's Manual

Press ರonkeypadorಯ ರonkeyfobfors.
Users can remote control the control panel via telephone, such as arm-away, arm-stay,
disarm, repeat alarm voice, and turn on / off site siren, etc. Users can call the phone
number set in the control panel. After ring attempts set, it will pick up with voice guide to
input password ending with “#”: “For arm- away, press 1, For arm-stay, press 2, For
disarm, press 3, For alarm repeat, press 5, turn-on siren, press 6, turn-off siren, press 7,
Hang up, press 0”.
The control panel will cal
l pre-set phone numbers when alarm triggered. Users will hear
voice alarm after pick-up and voice alarm will repeat after 5s stop. It will totally repeat 5
times. The control panel will automatically hung up in 5s after the 5th alarm. If there is no
voice alarm after pick-up or users don't want to wait, users can press “5” on your mobile
and the control panel will start playing voice alarm. Users can operate the control panel
during voice alarm stopping time, before the panel automaticall
y hung up.
See following:
Disarm: press “3”.
Arm-away: press “3” to disarm and then “1” to arm away.
Arm-stay: press “3” to disarm and then “2” to arm stay.
Repeat alarm: press “5” to repeat the alarm. Note: Alarm is not available to repeat after disarm.
Turn siren: press “ .
Turn siren: press “ .
Hang up: press “0” to hang up directly and the system will not dial any phone number.
on 6
off 7
Tele-control via phone
Dial to alarm via panel
-10-
Press ರonkeypadfors
Trigger fire alarm:
Pressing any key during voice play may cause communication error.
It is suggest to operate after voice. If the system is under programming, remote controlling is
not available. There should be no voice indication during remote .
on control panel or phone
controlling
Note
Figure - -11Figure - -10
SMS Operation
Users can proceed arm-away/arm-stay/disarm/status enquiry operation by sending SMS
to control panel. Please check below two ways of operation:
Method 1: Edit SMS manually, then send to control panel
-11-
Arm-away SMS
Operation succeeded or failed reply:
Arm-stay SMS
Operation succeeded or failed reply:
Disarm SMS
Operation succeeded or failed reply:
password0808disarm
ID: 1234
Prog: Disarm
Act:OK
ID: 1234
Prog: Disarm
Act:ERR
password0808armstay
ID: 1234
Prog: Arm stay
Act:ERR
ID: 1234
Prog: Arm away
Act:ERR
password0808armaway
ID: 1234
Prog: Arm stay
Act:OK
ID: 1234
Prog: Arm away
Act:OK
Suppose xxxx is user password. Users send SMS (passwordxxxxarmaway) to control panel, can
realize arm-away; send SMS (passwordxxxxarmstay) to control panel, can realize arm-stay; send
SMS. (passowrdxxxxdisarm) to control panel, can realize disarm.
For example: suppose user password is 0808, then the exact operation is as follow: