User's Manual

-04-
Note
Setting PGM trigged by programming setting, when meet trigged condition, PGM connected,
see pages related to PGM
PGM only compatible with low voltage (DC) control board. It shall not be connected with city
power (AC) directly.
N/C detector
N/O detector
Step 4: Power on the control panel
Wired Devices Connection
Figure -5-
The system supports different kinds of wired detectors with EOL resistance. Please connect as
following:
-05-
Step 5: Register Transmitters
To register a device:
Step 6: Testing the Chosen Mounting Location
Transmitter Test:
Note
Note
Re-check the wiring and make sure all connection is correct. Connect the AC power adaptor
and turn the backup battery on.
Parameters of power adaptor: Input: 100V-240VAC 50/60Hz 0.5A, Output:12VDC 1.5A.
Backup battery: 7.2V 800maH Li rechargeable,24 hours is required for full recharge which
can last around 8hours for this system under standby situation. After low battery warning,it
can work for around 30 minutes.
The system will keep the time and date with time chip powered. If the power of time chip runs out,
users need to re-set the time manually. The icon will move to next automatically after each input.
Press “ * ” to exit. After complete input, press “#” to confirm. If the input is not finished, and
meanwhile “ * ” is pressed, it will display on the LCD “Invalid Set!”. Pls press “ * ” to re-input it.
There will not alarm when anti-tamper was trigged, only flashing remind, In three hours power on.
Transmitters refer to wireless devices such as detector, magnetic contact, siren and keyfob, etc.
Only after enrolling can transmitters be recognized by the control panel.
1. During disarm, press “ ”. With voice guide “Enter password before setting parameters!”
Input the installer code with “ # ” .
2. For specific register process, pls refer to Device Set/Zone/WL.Register.
Please take off the battery before enrolling, and then enroll one by one with battery
connected. While users register with battery on for all devices, there may come wireless
signa linterference and make enroll fail.
Once all of the transmitters are registered, it is recommended that users test the chosen mounting
locations before permanently mounting the control panel and wireless devices. Users can test the
transmitter signal strength using the TX Test feature.
1. During disarm, press “ ”, with voice guide “ Enter password before setting parameters! ”.
Input the installer code with “ # ” to enter.
2. Select “8.Aided Test” ĺ“# ” ĺ“ 3.Transmitter test”ĺ“ # ”.
3. Trigger the desired devices, and the info about them will display on the LCD.
4. After all test, press “ * ” to exit.