User's Manual
-26- -27-
RFID Register
Same as wireless zones, pls refer to that.
Clear RFID
Same as wireless zones, pls refer to that.
6. Event Log
This system can save 200 event logs, including alarm and operation issues. When it exceeds 200,
it will substitute the earliest event
To query event
1. From the menu, select “ Event log ”, press “ # ” to enter. The earliest event will display.
2. Press “ / ” to query.
3. Press “ * ” to quit when finished.
7. System Option
Set Time/Date
Time and date must be set, or else the event log will be recorded with no time, arm or disarm may
not be realized, or system trouble will happen, voice guide will not work.
To set time and date:
1. Input time and date, ending with “ # ”.
During input, press “ * ” to quit. When finished, press “#” to confirm. Or if the time is not input
completely, but with “ # ” ending. It will indicate “Invalid set!” Then pres “ * ” to re-input.
Auto Arm/Disarm Time
It enables users to set auto arm/disarm time which is set in 24-hr system. Before this, the function
of auto arm/disarm must be turned on.
To set auto arm/disarm time
1. Select “ Arm time ” or “ Disarm Time ”, press “ # ” to enter, input time, and press “#” to save.
To turn on/off the function of auto arm/disarm:
1. Select “ Auto ON/OFF ”, press “ # ”.
2. Press “ / ” to select “ON” or “ OFF ”, ending with “ # ”. Press “ * ” to quit when finished.
Note
Time and date must be set, or else the auto arm or disarm function will be recorded with no time.
With no time set, auto arm/diarm function may be not available.
Volume
It enables users to activate or mute the speaker and meanwhile adjust the volume.
Supplementary Entry Delay
The Supplementary Entry Delay is a pre-alarm feature that is employed in the event that the
system is not disarmed during the entry delay. And the period is set as 5s. While this function is
turned off, the system will alarm immediately after entry delay.
Window/Door open remind
This option enables users to turn ON/OFF the function of window/door open remind. The panel
will detect the situation of Magnet and remind users “Door or Window is Open” when users arm
the system. If Zone malfunction is allowed to display, the system will remind and display “system
trouble” . It will disappear after users close the window.
Arm with open Doors
User is allowed to set if the system can be armed while window/door is open. If setting is “ON”,
Arm with open doors is allowed. Otherwise it will be prohibited.
Note
This function only works with “Window / Door open remind” is “ON”.
Initialize All
The Initialization function clears programming of the whole system and restore factory defaults.
8. Aided Test
Siren Test
Siren test is strongly recommended periodic for safety, which includes wired siren, wireless siren
and built-in siren. Select the type of siren ending with “ # ” to test. After test, press “ # ” to continue
another test. Or “ * ” to finish.
Walk Test
It enables users to make sure if the detectors work normally, which is strongly recommended to do
periodically.
To set walk test
1. Select “ Walk test ”, press “ # ”, All registered detectors will display on LCD with the voice guide
as “Walk test starts, transmit wireless signal!”