User's Manual
Note
2. Trigger the wireless asap to avoid any interference.
3. The system will remind to save after receiving the signal. Press “ # ” to save, or “ * ” to re-register.
During register, if the signal is received for registered code, it will indicate as registered. If the code
is in wrong format, it will indicate as wrong. If no code is received within 60s, the system indicate
“Enrolling failed!”.
To register by code input
1. If the code is input before, it will remind if users want to re-register, press “#” to continue, or “ * ”
to exit.
2. Input the ID, ending with “ # ”.
3. The LCD will remind if need change the name. Press “ # ” to confirm. Or “ * ” to quit.
4. Press “ * ” to quit.
Zone Naming
Details refer to the page “User Account Naming”
Clear WL
This enables users to remove the wireless devices by clearance. For the supervision function, If
the device is removed without clearance, the system will remind trouble for device loss.
To Clear WL
1. Select “ Clear WL.”, press “ # ”, select “ Clear single ” or “ Clear All ”.
2. If “Clear single”, select the zone number ending with “#”. While “Clear all” means to clear all
enrolled wireless transmitters.
Set Zone Type
To set zone type
Select “Set zone type”, press “ # ”.
1. Press the navigation key to select the zone users desire to set ending with “ # ”, and then select
the zone type for it ending with “ # ” to save it.
2. Press “ * ” to exit.
Entry Delay
Entry delay means a period for user to enter detection area, activate the delay zone and disarm
before the system alarms. Times can be set from 0 seconds (no delay) up to 300 seconds in 1 second
increments.
-22-
Ɣ 100 seconds is the factory default.
-23-
Exit Delay
A period for user to leave detecting area once the system armed. Zones with exit delay will not
alarm during this period. Times can be set from 0 seconds (no delay) up to 300 seconds in 1
second increments.
Ɣ 100 seconds is the factory default.
Zone Siren Set
It enables the user to active or mute external siren for some zone.“ ON ” enables the siren to
buzzer during alarm, while “ OFF ” enables the siren dummy. This function is available for
Zones No. 1-16,31-46 (wireless zones), 21-22(wired zones), No.17 and 19.
Chime Zone Set
It is only available for entry/exit zones to enable the “Chime zone Function”. During disarm,
trigger the zone, the voice of “ Ding Dong! ” will be given off.
Wireless Zone Supervision
Wireless devices will transmit supervision signal to the control panel at intervals. If the system
does not receive any signal, then the transmitter is regarded as loss. The max loss period is
called supervision time. If no signal is transmitted during this period, wireless zone trouble
appears in the list of system trouble. Times can be set from 2 hours to 99 hours.
Ɣ 24 hours is the factory default.
Ɣ The period supervision function is closed of all the zones as the factory default.
Max Alarm Times
Users can set one zone with max continuous alarm attempts, default will be 3. After disarm,
the device will restart counting.
Zone Trouble Indication
This option enables users to select whether zone trouble will be indicated in the system trouble
list. If this function is turned off, it will not display.
Keyfob Register
Same as wireless zones, pls refer to that.
Clear Keyfob