User's Manual

Keypad Lock and Unlock
If the code is input wrong, the voice will guide “ Wrong password, please re-input!
And if the code is input wrong for 5 times,the voice will indicate “Access locked, please try later! ”DŽ
After the code is locked, and operate any step which requires code, the voice will guide
Access locked, please try later!
If the code is locked when there is no alarm, but alarm occurs after the code lock, the system
will auto release the code lock. While if the code is locked after alarm, auto release must be
available after system re-initializa
tion, or within 30 minutes.
Codes Access
There are 5 types of codes: master code, installer code, duress code, temporary code, and
user code (4). Different authorizations are appointed for different codes.
Ĝ means for authority(“ ):
Code Type
Arm&disarm
Enter Menu Code Set “Programming” in menu
Editable
Clearable
Master Code
Installer Code
Duress Code
Temp Code
User code 1
-16-
User code 2
User code 3
User code 4
Remark: ķEnter by master code, users can set all codes except installer code.

ĸEnter by installer code, can only set installer code.
Code Restore
users
Figure - -12
If users forget code, it need power off the panel, open the panel back, turn jumper to “default”
mode, restart the panel to restore code to factory default setting. Then users should turn jumper
to another side, or the panel will restore code when restarting panel next time.
Zone Description
There are 8 types of zones: entry/exit zone, active zone, perimeter zone, panic zone,
fire zone, gas zone, tamper zone and duress zone.
There are 38 zones: zone 1-16/31~46 is wireless. Zone 17 is panic. Zone 18 is duress.
Zone 19 is fire. Zone 21-22 is wired. Zone 30 is tamper. Different zone type alarms in
different ways. Tamper alarm is valid with 24 hours for wireless zone 1-16 . with
tamper alarm indication.
/31~46
-17-
Entry/Exit
Active
Perimeter
Panic
Fire
Gas
Tamper
Duress
Invalid
Invalid
No
No
No
No
No
No
Invalid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Valid
Invalid Yes
Valid
Valid Yes
Zone
Type
Valid or not
when disarm
Valid or not
when away
Valid or not
when stay
Exit
Delay
Entry
Delay
Sound
and flash
Type
number
Mount position
or detector
Gate
Indoor
Veranda window
Panic button
Fire detector
Gas detector
Tamper switch
Emergency button
No
No
No
No
No
N
o
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Chime Zone
It enables the panel with alarm with entry delay during arm, or issue Ding Dong!”under
disarm.
Note : The chime zone function only works for entry/exit zone.
Table 3: Zone Number
Zone Number
Bypass or not Type
Remark
Applicable
Applicable Applicable
Applicable Applicable
Applicable
N/A N/A
N/A
N/A N/A
N/A
wireless
panic
duress
fire
wired
panel tamper
1~16/31~46
17
18
19
21~22
30
Table 2: Zone Type
Default
ON
OFF
DC12V