Wiring Diagram
Jiangsu JWT Electronics Shares CO.,Ltd.
34 / 42
5、RSSI
Support RSSI detection function, in RX state, can read real-time RSSI directly through
reg0x11[15:8]
(1)、Set the chip to the RX state;
(2)、The reg0x1c[15] was first written as 1, and the RSSI was closed to eliminate the remaining
RSSI values. Then, the reg0x1c[15] is then written as 0, and the RSSI detection function is opened.
After waiting for 60us, the current RSSI value can be read through reg0x11 [15:8].
The following figure is the measured performance of the chip RSSI detection function: