8.0 User-maintenance
Disconnect machine from air
supply before performing any maintenance. If
head guard is removed for servicing, reinstall
guard before operating machine. Failure to
comply may cause serious injury.
1. Periodically insert oil into two fittings (A, Figure
9-1)
2. Periodically apply oil to pivot areas of
connection plate (B).
Figure 9-1
3. Drain water from air compressor tank daily, as
well as any condensation from air lines. Change
filters on the air system on a regular basis.
4. Periodically check filter/regulator bowl (F,
Figure 5-2) for fluids or sediment accumulation,
and empty if needed. Bowl should be emptied
before fluid reaches maximum drain level as
indicated on bowl. To remove a bowl, shut off
air supply and push pin (G, Figure 5-2) to bleed
excess air. Then press tab, rotate bowl to the
left, and pull bowl down. Reverse procedure to
reinstall bowl. Make sure bowl is locked in
position before applying air to the system!
5. Maintain oil level in lubricator bowl (H, Figure 5-
2); top off as needed with ISO 32 (SAE 10) non-
detergent, non-additive oil. Remove screw (J,
Figure 5-2) with screwdriver to fill.
6. Keep table and T-slots clean and free of rust.
Periodically apply a light coat of SAE 30 oil or
equivalent to exposed metal surfaces, such as
table, fences and blades.
7. Check air connections; replace components if
leakage is found.
8. Keep blade area free of deposits or shavings,
which can impede cut quality and hasten blade
wear.
9. Maintain sharp blades. If they become dull,
remove and re-sharpen.
8.1 Additional servicing
Any additional servicing should be performed by
authorized service personnel.