Manual
4
MVP Group Corp - 5659 Royalmount Ave., Montreal, QC, Canada H4P 2P9
Tel: 514.737.9701 / 888.275.4538 - Fax: 514.342.3854 / 877.453.8832
sales@mvpgroupcorp.com - www.mvpgroupcorp.com
WARNING: The chemicals used in commercial glass washing are very harsh. Exposure to human skin can cause severe
burns. Chemical containers should be stored in a manner and/or location that prevents them from spilling or splashing.
Chemical containers must be secured. Please consult your chemical vendor to ensure proper storage or call the Jet-Tech
factory to purchase an accessory chemical storage drawer, part number 01001500.
1. Place chemical Feed Lines into the proper chemical containers.
Red - Detergent
Blue - Rinse Aid
Clear - Sanitizer
2. After utility connections described on page 2 are completed, plug in glasswasher.
3. Prime Chemical Pumps: Slide cover open to view chemical inlets.
Depress Prime switches to fill Feed Lines (see page 6 - Control Panel Operation).
Stop priming when chemicals come out of inlets.
NOTE: Always run a complete cycle or dump clean water in the tank after using the
prime switches. Undiluted chemicals will damage stainless steel.
4. Fill Level Adjustment: Cycle the glasswasher to check water fill level (water fill level
is preset at the factory but may require adjustments due to variations in water pressure/flow at installation location).
With the sliding cover open, initiate cycle by pressing Cycle Start (see page 6 - Control Panel Operation).
When fill is complete, verify that the water level is at the FILL mark (top of the drain screen handle - see photo
below).
If water level is correct, skip to Step 5.
If water level is above or below the fill mark, fill adjustment is required.
• Unplug glasswasher and remove front panel.
• Adjust the Fill adjustment knob on the circuit board. Turn knob clockwise to increase fill time or counter-
clockwise to decrease fill time.
• Leaving the sliding cover open will end the cycle and drain the tank after 30 seconds and cycle can be re-
started to check water level again.
Once water level is correct, continue with Step 5.
start-up InstructIons
Circuit board slides
out for easy access
Adjust circuit board knobs as neededFILL mark - top of drain screen handle
Chemical inlets