Use and Care

Maintenance
Fill the dishwasher;
1) To begin, you need to turn the black swivel switch clockwise a quarter turn to the ON
position.
2) Fill the wash tank with water by pressing the round black fill button .
Open the door to monitor the water
level, push and hold the black fill
button until the water has reached
an inch above the bottom. This
needs to be done only if the wash
tank is empty. The dishwasher will
refill itself automatically at every
cycle.
Begin Loading:
3) Load a rack of cups and glasses and slide into the dishwasher. Close the door.
4) Press the cycle button (black round button on the right) to start the wash cycle.
a. The wash and rinse cycle takes 90 seconds. The dishwasher will automatically
pump in the proper amount of detergent, rinse-aid and sanitizer.
5) Once the cycle is done, the indicator light will switch Off.
Drain the unit:
At the end of the day, or if the water needs to be emptied, you can drain the dishwasher by
pressing and holding the white button. You need to hold for several seconds (about 30
seconds).
Note: Do not run the dishwasher without any water.
Make sure the power switch is turned off at night.
(on the left side)
10
POWER LIGHT
POWER SWITCH
THERMOMETER DIAL
FILL BUTTON
DRAIN BUTTON
CYCLE BUTTON
CYCLE LIGHT
Operation
SThis dishwasher requires daily maintenance. The most important part is to
keep the interior clean. In the sump area, you will find a round screen. This
round screen can be removed easily and must be cleaned at least once a
day.
SChemical containers should be checked daily for quantity. If they are low on
product, replace them.
SDepending on the water quality, the dishwasher should have a descaling
treatment on a weekly basis. To do a descaling treatment, put a cup (250ml)
of descaling solution in the dishwasher once it is filled with water. Run the
dishwasher twice.
SThe spray jets should be inspected for obstruction once a month. If blocked, the upper jets
can be unscrewed and cleaned under running water. The rotating spray arm can be removed
by unscrewing the center knob.
SThe bottom panel below the door, should be opened and the chemical pumps checked for
leaks also once a month.