Use and Care
CHEMICAL PUMPS
Models 727, 737, 747, 767, F-14, F-16DP, F-18, F-18DP, F-20 & F-22 are supplied with
factory installed liquid detergent and rinse additive pumps to automatically dispense during
each wash & rinse cycle. Before accessing the bottom section of the dishwasher, make sure
that the power is turned off at the
source (breaker panel).
The bottom panel can only be
removed with a flat tool like a screw-
driver. Insert the screw-driver in the
gap between the front panel and the
side panel. Pry open towards you.
Do this on both sides.
The red & blue hoses connected to the pumps must be routed out of the
bottom of the dishwasher. The red tube is for detergent and the blue tube is for
rinse additive. The containers can be either to the right or left of the
dishwasher. Perforating the stainless panel is not recommended.
The two chemical pumps are factory adjusted to accommodate most installations.
There is a mark on the pump indicating this setting.
It is recommended that only qualified personnel alter these settings.
UNDER NO CIRCUMSTANCES should the detergent pump be
turned off.
18
RINSE ADDITIVE
BLUE TUBE
DETERGENT
RED TUBE
F-18DP