4.6 Calibrating the detergent and rinse aid pumps
The chemical pumps are set in the "OFF" position at the factory. Once the machine is installed, it is
necessary to activate and calibrate the detergent and rinse aid measuring devices by following these
instructions:
Turn off the machine, lift the hood or open the door and keep the C and D buttons pressed for 5 seconds.
The following will then appear:
Display the following by using the C button:
Confirm the entry to the main menu mode using the D button
Then scroll the various menu items using the A button until the following appears:
detergent pump
Now it is possible to enable the measuring device by keeping button D pressed
:
The word off switches to on. Keep it on until it is apparent that the detergent delivery pipe has become filled.
Again pressing the button go to the wording rinse aid pump”.
Fill the rinse aid measuring device pipes following the same instructions provided for the detergent
measuring device.