Use and Care Manual
8. Clean the main body
1. Wipe the body with a clean soft cloth dampened with the diluted cleaning agent.
2. Wipe the body clean with a soft wet rag stained with clean water.
3. Dry the body with a clean dry rag.
Assembly of Parts
All parts that have been cleaned and sterilized must be reinstalled correctly.
Some parts must be guaranteed to moisturize so that they can be used for a longer time.
• Assembly of bell mouth sealing ring
• Assembly of stirrer
Put the rear sealing ring of the evaporator into the base of the evaporator, and then smear Vaseline
on the outer surface of the sealing ring behind the evaporator. Install the assembled stirrer into the
evaporator, and the end of the stirrer is inserted into the drive shaft. Then, push the stirrer
forward gently and rotate the stirrer until the stirrer limit head just snaps into the limit of the drive
shaft,and the bell mouth sealing ring can come into contact with the evaporator.
Place the bell mouth sealing ring in the groove
in the front of the stirrer.
Limiting head of the stirrer
Drive shaft
Limit of the drive shaft
Evaporator
Limit of the drive shaft
Evaporator base
Bell mouth
sealing ring.
Stirrer groove.
Smear Vaseline
17