Dimensions Sheet
JENN-AIR
®
 DETAILED PLANNING DIMENSIONS
3 of 3
8116AdZw915
IMPORTANT: Dimensional specifications are provided for planning purposes only.  
Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide 
before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation. 
All Jenn-Air
®
 appliances are appropriately UL, CUL or CSA approved.
OPENING/CLEARANCE DIMENSIONS
48" SIDE-BY-SIDE REFRIGERATORS WITH ICE & WATER DISPENSER
JS48PPDUDE – 48
3
⁄8" x 83
3
⁄8" x 27
3
⁄4" (with handles) 
JS48SSDUDE – 48
3
⁄8" x 83
3
⁄8" x 27
1
⁄8" (with handles)
w
D
A
F
C
C
B
E
e
Water 
Shutoff
A B
C
D
E
J
F
I
H
A*
B*
F
E
D
C
G
110º
K
L
N
O
P
Q
110º
M
M
R
BUILT-IN SIDE BY SIDE WITH/DISPENSER
MODEL JS48SEDUDW
G
MODEL #
JS48PPDUDE 
JS48SSDUDE
in cm
A
Width (min.) 47
1
⁄2 120.7
B
Width of recommended electrical 
location
13
1
⁄2 34.3
C
Distance from side of cabinet to 
recommended water connection 
location
6 15.2
D
Height (min.) 84 213.4
E
Height to recommended electrical 
location
77 195.6
F
Depth of recommended water 
connection location (max.)
1 2.5
e
Recommended electrical connection location
w
Recommended water connection location
ELECTRICAL REQUIREMENTS
115 volt, 60 Hz, AC only, 15- or 20-amp fused, grounded circuit is 
required. A dedicated circuit is recommended. Use an outlet that cannot 
be turned off by a switch. 
Minimum length of power cord is 84" (213.4 cm). Do not use an extension 
cord.
WATER PRESSURE REQUIREMENTS
A cold water supply with water pressure between 30 and 120 psi (207 and 
827 kPa) is required to operate the water dispenser and ice maker. Call a 
licensed, qualified plumber with any questions about the water pressure.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water coming out of a reverse osmosis 
system going to the water inlet valve of the refrigerator needs to be 
between 30 and 120 psi (207 and 827 kPa).
If a reverse osmosis water filtration system is connected to the cold water 
supply, the water pressure to the reverse osmosis system needs to be a 
minimum of 40 to 60 psi (276 to 414 kPa).
LOCATION REQUIREMENTS
Floor must be able to support refrigerator (more than 600 lb [272 kg]) 
and contents of the refrigerator and must be at the same level as flooring  
in the room.
FRONT VIEW
BACK VIEW