Dimension Guide

DETAILED PLANNING DIMENSIONS
3 of 8
IMPORTANT: Dimensional specications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All JennAir
®
appliances are appropriately UL, CUL or CSA approved.
JENNAIR
®
SMALL SPEED OVEN - STANDARD INSTALLATION
JMC6224HM – 23
7
16
" X 18
5
16
" X 24" (Depth With Handle)
JMC6224HL – 23
7
16
" X 18
5
16
" X 24
5
8
" (Depth With Handle)
OPENING/ CLEARANCE DIMENSIONS
A
D
B
C*
E
e
F
e
G
FRONT VIEW SIDE VIEW
A
H
e
B
C*
e
g g
I
Power Supply
Location
UNDER COUNTER INSTALLATION
(without cooktop installed above)
BACK VIEW
MODEL #
JMC6224HM
JMC6224HL
in cm
A Width of cabinet (min.) 23
5
8
60
B Width of cutout 21
15
16
55.8
C* Height of cutout (recommended) 17
3
4
45
D
Top of cutout to bottom of upper
cabinet door (min.)
1/2 1.2
E
Bottom of cutout to top of lower
cabinet door (min.)
1/2 1.2
F** Bottom of cutout to oor (min.) 36
9
16
92.8
G Depth of cutout (min.) 21
1
16
53.5
H
Top of cutout to underside of
countertop (min.)
1/2 1.2
I Bottom of cutout to oor 1/2 1.2
e Recommended junction box location
*Will t cutout height from 17
9
16
" (44.6 cm) to 17
15
16
"(45.6 cm)
**Minimum dimension only for Canada market
ELECTRICAL REQUIREMENTS
208 V or 240 V, 60 Hz, 20 A fused, grounded circuit is required.
Adedicated circuit is required.
The length of conduit provided is for serviceability. Do not cut
the conduit. The junction box should be located 3" (7.6cm)
maximum below the support surface. Drill a 1" (2.5 cm)
minimum diameter hole in the right rear or left rear corner of the
support surface for access to the junction box.
NOTE: For under counter installation, the junction box should
be located in the adjacent right or left cabinet. Drill a 1" (2.5 cm)
minimum diameter hole in an upper corner of the side wall for
access to the junction box.