Dimension Guide
DETAILED PLANNING DIMENSIONS
3 of 8
IMPORTANT: Dimensional specications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All JennAir
®
appliances are appropriately UL, CUL or CSA approved.
JENNAIR
®
SMALL SPEED OVEN - STANDARD INSTALLATION
JMC6224HM – 23
7
⁄
16
" X 18
5
⁄
16
" X 24" (Depth With Handle)
JMC6224HL – 23
7
⁄
16
" X 18
5
⁄
16
" X 24
5
⁄
8
" (Depth With Handle)
OPENING/ CLEARANCE DIMENSIONS
A
D
B
C*
E
e
F
e
G
FRONT VIEW SIDE VIEW
A
H
e
B
C*
e
g g
I
Power Supply
Location
UNDER COUNTER INSTALLATION
(without cooktop installed above)
BACK VIEW
MODEL #
JMC6224HM
JMC6224HL
in cm
A Width of cabinet (min.) 23
5
⁄
8
60
B Width of cutout 21
15
⁄
16
55.8
C* Height of cutout (recommended) 17
3
⁄
4
45
D
Top of cutout to bottom of upper
cabinet door (min.)
1/2 1.2
E
Bottom of cutout to top of lower
cabinet door (min.)
1/2 1.2
F** Bottom of cutout to oor (min.) 36
9
⁄
16
92.8
G Depth of cutout (min.) 21
1
⁄
16
53.5
H
Top of cutout to underside of
countertop (min.)
1/2 1.2
I Bottom of cutout to oor 1/2 1.2
e Recommended junction box location
*Will t cutout height from 17
9
⁄
16
" (44.6 cm) to 17
15
⁄
16
"(45.6 cm)
**Minimum dimension only for Canada market
ELECTRICAL REQUIREMENTS
208 V or 240 V, 60 Hz, 20 A fused, grounded circuit is required.
Adedicated circuit is required.
The length of conduit provided is for serviceability. Do not cut
the conduit. The junction box should be located 3" (7.6cm)
maximum below the support surface. Drill a 1" (2.5 cm)
minimum diameter hole in the right rear or left rear corner of the
support surface for access to the junction box.
NOTE: For under counter installation, the junction box should
be located in the adjacent right or left cabinet. Drill a 1" (2.5 cm)
minimum diameter hole in an upper corner of the side wall for
access to the junction box.