Dimension Guide
DETAILED PLANNING DIMENSIONS
4 of 8
W11318374B
Installation Instructions: W11260095
JENNAIR
®
SMALL STEAM OVEN - FLUSH INSTALLATION
JJW6024HM – 23
7
⁄
16
" X 18
5
⁄
16
" X 20
3
⁄
8
" (Depth Without Handle)
JJW6024HL – 23
7
⁄
16
" X 18
5
⁄
16
" X 20
3
⁄
8
" (Depth Without Handle)
IMPORTANT: Dimensional specications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All JennAir
®
appliances are appropriately UL, CUL or CSA approved.
®
/™ ©2019 JennAir. All rights reserved. Used under license in Canada.
OPENING/CLEARANCE DIMENSIONS
A
1/4" (0.6 cm)
Top Cleat*
3/4" x 1" (1.9 x 2.5 cm)
width x min. thickness
Side Cleat*
3" x 1/2" (7.6 cm x 1.3 cm)
Width x Height
Spacer (entire
depth
of cutout)
B
C
D
e e
E
FRONT VIEW
e e
Spacer (entire
depth of cutout)
5/16" (0.8 cm)
Top Cleat*
3/4" x 1" (1.9 x 2.5 cm)
width x min. thickness
Side Cleat*
3" x 1/2" (7.6 cm X 1.3 cm)
Width X Height
A
B
C
D
13/16" (2.1 cm)
Side Cleat* Side Cleat*
E
Power Supply
Location
BACK VIEWTOP VIEW
MODEL # JJW6024HM
JJW6024HL
in cm
A Width of ush inset cutout (min.) 23
11
⁄
16
60.2
B Width of opening (min.) 22 55.9
C Height of ush inset cutout (min.) 19
9
⁄
16
47.2
D Height of opening (min.) 18
7
⁄
8
46.6
E Depth of cutout (min.) 20
7
⁄
16
51.8
e Recommended junction box location
ELECTRICAL REQUIREMENTS
120 V, 15 A fused, grounded circuit is required. A dedicated
circuit is required.
The length of conduit provided is for serviceability. Do not cut the
conduit. The junction box should be located 3" (7.6cm) maximum
below the support surface. Drill a 1" (3.4 cm) minimum diameter
hole in the right rear or left rear corner of the support surface for
access to the junction box.
NOTE: For under counter installation, the junction box should
be located in the adjacent right or left cabinet. Drill a 1" (2.5cm)
minimum diameter hole in an upper corner of the side wall for
access to the junction box.
FLUSH INSTALLATION REQUIREMENTS
A 20
7
⁄
16
" (51.8 cm) minimum cutout depth is required. These
dimensions will result in a 1/8" (0.3 cm) reveal on the top, a
1/8"(0.3 cm) reveal on the sides and a 1/8" (0.3 cm) reveal on the
bottom of the wall oven.
The front face of the cleats and spacers will be visible and should
be treated as a nished surface.
CABINET REQUIREMENTS
NOTE: When using under counter installation, check cabinet
manufacturer’s specications to verify t.
SIDE VIEW
*Cleats and spacers must be recessed 13/16" (2.1 cm) from the front of the cabinet.
UNDER COUNTER INSTALLATION
(without cooktop installed above)