Dimension Guide

DETAILED PLANNING DIMENSIONS
3 of 8
IMPORTANT: Dimensional specications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All JennAir
®
appliances are appropriately UL, CUL or CSA approved.
JENNAIR
®
SMALL STEAM OVEN - STANDARD INSTALLATION
JJW6024HM – 23
7
16
" X 18
5
16
" X 22
1
2
" (Depth With Handle)
JJW6024HL – 23
7
16
" X 18
5
16
" X 23
3
16
" (Depth With Handle)
OPENING/CLEARANCE DIMENSIONS
A
D
B
C*
E
e
F
e
FRONT VIEW SIDE VIEW
A
G
H
e e
g g
C*
B
Power Supply
Location
UNDER COUNTER INSTALLATION
(without cooktop installed above)
BACK VIEW
MODEL #
JJW6024HM
JJW6024HL
in cm
A Width of cabinet (min.) 23
5
8
60
B Width of cutout 21
15
16
55.8
C*
Height of cutout
(recommended)
17
3
16
45.3
D
Top of cutout to bottom of
upper cabinet door (min.)
1/2 1.2
E
Bottom of cutout to top of
lower cabinet door (min.)
1/2 1.2
F Depth of cutout (min.) 19
9
16
49.7
G
Top of cutout to underside
of countertop (min.)
1/2 1.2
H
Bottom of cutout to oor
(min.)
1/2 1.2
e Recommended junction box location
*Will t cutout height from 17
3
4
" (45 cm) to 17
15
16
"(45.6 cm)
ELECTRICAL REQUIREMENTS
120 V, 15 A fused, grounded circuit is required. Adedicated
circuit is required.
The length of conduit provided is for serviceability. Do not cut
the conduit. The junction box should be located 3" (7.6cm)
maximum below the support surface. Drill a 1" (2.5 cm)
minimum diameter hole in the right rear or left rear corner of the
support surface for access to the junction box.
NOTE: For under counter installation, the junction box should
be located in the adjacent right or left cabinet. Drill a 1" (2.5 cm)
minimum diameter hole in an upper corner of the side wall for
access to the junction box.