Dimension Guide

DETAILED PLANNING DIMENSIONS
4 of 8
W11318374B
Installation Instructions: W11260095
JENNAIR
®
SMALL STEAM OVEN - FLUSH INSTALLATION
JJW6024HM – 23
7
16
" X 18
5
16
" X 20
3
8
" (Depth Without Handle)
JJW6024HL – 23
7
16
" X 18
5
16
" X 20
3
8
" (Depth Without Handle)
IMPORTANT: Dimensional specications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All JennAir
®
appliances are appropriately UL, CUL or CSA approved.
®
/™ ©2019 JennAir. All rights reserved. Used under license in Canada.
OPENING/CLEARANCE DIMENSIONS
A
1/4" (0.6 cm)
Top Cleat*
3/4" x 1" (1.9 x 2.5 cm)
width x min. thickness
Side Cleat*
3" x 1/2" (7.6 cm x 1.3 cm)
Width x Height
Spacer (entire
depth
of cutout)
B
C
D
e e
E
FRONT VIEW
e e
Spacer (entire
depth of cutout)
5/16" (0.8 cm)
Top Cleat*
3/4" x 1" (1.9 x 2.5 cm)
width x min. thickness
Side Cleat*
3" x 1/2" (7.6 cm X 1.3 cm)
Width X Height
A
B
C
D
13/16" (2.1 cm)
Side Cleat* Side Cleat*
E
Power Supply
Location
BACK VIEWTOP VIEW
MODEL # JJW6024HM
JJW6024HL
in cm
A Width of ush inset cutout (min.) 23
11
16
60.2
B Width of opening (min.) 22 55.9
C Height of ush inset cutout (min.) 19
9
16
47.2
D Height of opening (min.) 18
7
8
46.6
E Depth of cutout (min.) 20
7
16
51.8
e Recommended junction box location
ELECTRICAL REQUIREMENTS
120 V, 15 A fused, grounded circuit is required. A dedicated
circuit is required.
The length of conduit provided is for serviceability. Do not cut the
conduit. The junction box should be located 3" (7.6cm) maximum
below the support surface. Drill a 1" (3.4 cm) minimum diameter
hole in the right rear or left rear corner of the support surface for
access to the junction box.
NOTE: For under counter installation, the junction box should
be located in the adjacent right or left cabinet. Drill a 1" (2.5cm)
minimum diameter hole in an upper corner of the side wall for
access to the junction box.
FLUSH INSTALLATION REQUIREMENTS
A 20
7
16
" (51.8 cm) minimum cutout depth is required. These
dimensions will result in a 1/8" (0.3 cm) reveal on the top, a
1/8"(0.3 cm) reveal on the sides and a 1/8" (0.3 cm) reveal on the
bottom of the wall oven.
The front face of the cleats and spacers will be visible and should
be treated as a nished surface.
CABINET REQUIREMENTS
NOTE: When using under counter installation, check cabinet
manufacturer’s specications to verify t.
SIDE VIEW
*Cleats and spacers must be recessed 13/16" (2.1 cm) from the front of the cabinet.
UNDER COUNTER INSTALLATION
(without cooktop installed above)