Installation guide
Py
Location
Rea
AWARNING
°
soll
%
#
Saitvmnnwt
tel
avin
The
water
shutoff
should
be
located
in
the
base
cabinet
on
either
side
of
the
refrigerator
or
some
other
easily
accessible
area.
If
the
water
shutoff
valve
is
not
in
the
cabinets,
the
plumbing
for
the
water
line
can
come
through
the
floor.
See
“Water
Supply
Requirements”
for
more
information.
Explosion
Hazard
Keep
flammable
materials
and
vapors,
such
as
gasoline,
away
from
refrigerator.
Failure
to
do
so
can
result
in
death,
explosion,
or
fire.
IMPORTANT:
m
Observe
all
governing
codes
and
ordinances.
gm
|tis
recommended
that
you
do
not
install
the
refrigerator
near
an
oven,
radiator,
or
other heat
source.
gm
Do
not
install
in
a
location
where
the
temperature
will
fall
below
55°F
(13°C).
mg
Floor
must
support
the
refrigerator
weight,
more
than
600
Ibs
(272
kg),
door panels
and
contents
of
the
refrigerator.
g
Ceiling
height
must
allow
for
side
tipping
radius.
See
“Tipping
Radius.”
mg
Location
should
permit
door
to
open
fully.
See
“Door
Swing
Dimensions.”
gm
Location
must
permit
top
grille
removal.
See
“Opening
Dimensions.”
at
=
HH
g0"-90"
ae
11(203-229
cm)!
Dimension
84"
(213.4
cm)
to
bottom
of
solid
soffit
77"
(196
cm)
—_—————————_
A
Width
(see
chart
following)
Opening
Dimensions
The
width
of
the
opening,
from
side
to
side,
must
be
as
specified
for
your
model,
for
at
least
2"
(5.08
cm)
back
from
the
face
of
the
cabinet.
NOTE:
If
your
opening
does
not
meet
this
requirement,
you
will
need
to
make
modifications.
A
solid
soffit
or
wall
cabinet
must
be
installed
84"
(213.4
cm)
above
the
floor.
If
the
solid
soffit
is
higher
than
84"
(213.4
cm)
or
one
is
not
available,
then
the
refrigerator
must
be
braced.
If
the
anti-tip
boards
are
needed,
they
must
be
attached
to
the
rear wall
studs
so
that
there
is
84"
(213.4
cm)
from
the
bottom
of
the
anti-tip
board
to
the
floor.
See
“Install
Anti-Tip
Boards”
for
more
information.
For
a
fully
integrated
installation,
a
minimum
of
6"
(15.24
cm)
of
open
space
above
the
refrigerator
is
required.
See
“Fully
Integrated
Installation.”
Anti-tip
boards
are
required.
See
“Install
Anti-Tip
Boards”
for
more
information.
A
grounded
3
prong
electrical
outlet
should
be
located
within
a
specified
number
of
inches
from
the
right-hand
side
cabinets
or
end
panel.
See
the
chart
following
the
graphic
for
ni
c
4"
t
=o]
}
G-etem)
ees
Model
|
Width
A
Dimension
B
(as
shown
above)
(as
shown
above)
36
36" (91.4
cm)
42
4"
(10.2
cm)
42"
(106.7
cm)
10"
(25.4
cm)
Installation
Type
Depth
C
(as
shown
above)
the
number
of
inches
required
for
your
model.
For
more
information,
see
“Electrical
Requirements.”
Standard
Flush
(new
installation)
25" (63.5
cm)
minimum
Retrofit
Installations
24"
(60.9
cm)
minimum
IMPORTANT:
mg
The
width
of
the
opening
(Width
A),
must
be
as
specified
for
your
model,
for
at
least
2"
(5.08
cm)
back
from
the
face
of
the
cabinet.
NOTE:
If
your
opening
does
not
meet
this
requirement,
you
will
need
to
make
modifications.
gm
Flooring
under
refrigerator
must
be
at
same
level as
the
room.
Face
of
cabinetry
must
be
plumb.