Specification
PRODUCT GUIDE
Interior & Exterior Doors (JPG013)
4
DOOR SWEEP (INSWING DOORS ONLY)
The door sweep is mounted on the bottom of the door slab and lls the 
gap between the threshold and the slab. Due to continual contact with 
the threshold, the door sweep may lose its shape and cease to provide 
an effective seal.
1. Remove slab.
2. Lay slab on at 
padded work surface.
3. Remove staples in 
door sweep with 
needle nose pliers or 
side cutters.
4. Pull door sweep 
loose by starting at 
one end and working 
to the other.
5.Cleanoldsealantoff
rail with putty knife.
6.Trimnewdoorsweep
to same length as the 
existing one.
7. Cover face (the side with the barbs) of new door sweep with silicone 
sealant.
8.Workattachmentbarbsintokerfsfromoneendofthepaneltothe
other.
9.Securesweeptothedoorpanelwithstaplesandwipeoffsealant
squeeze-out. Seal the sweep on both ends with silicone sealant. 
Reinstall slab.
WEATHERSTRIP REPLACEMENT
ORDERING NEW WEATHERSTRIP
Weatherstrip gaskets and foam wedges are critical to water and air 
inltration control. Check placement and quality of weatherstrip. 
Replace if damaged.
Fire-rated doors require specic weatherstrip. Please contact us if 
replacing weatherstrip in a re-rated door.
Doors will have weatherstrip in the frame where the slab(s) are when 
normally closed. Some doors have a sweep attached to the bottom of 
the operating panel where it contacts the threshold. Double doors will 
have weatherstrip in the astragal.
Information for Replacement Weatherstrip
Product Identication
Weatherstrip Location
Weatherstrip Type
Color
Amount Needed
1. Determine amount needed by measuring each piece to be replaced. 
Note the location on the door of each type of weatherstrip.
2. For each type of weatherstrip, add all measurements, then add an 
additional 10%.
3. Round up to the nearest foot.
4. Fill out the following table.
Possible Weatherstrip Locations on Double Doors
5.Purchasenewweatherstripfromalocalsupplier.
FRAME/THRESHOLD/ASTRAGAL/MULLION WEATHERSTRIP
When replacing both 
the side and the head 
weatherstrip in the 
frame, install head 
weatherstrip rst. 
Astragal weatherstrip 
runs vertically along 
the astragal (between 
the two slabs of double 
doors).
1. Open active panel.
2. Grip weatherstrip 
and gently pull out 
of kerf.
When replacing 
frame weatherstrip, 
if applicable, trim 
and overlap the new 
weatherstrip in the 
same way as the old 
weatherstrip.
1. Cut new weatherstrip 
to length.
2. Work the attachment 
barb into the kerf 
from one end to the 
other.
Threshold
Door 
Sweep
Head 
weatherstrip
Side jamb 