Instruction Manual

2
2.
Remove and discard original Lock-up
valve and springs. Install NEW Con-
version Valve, Pin and Slug as shown.
RE-INSTALL THE ORIGINAL WASHER
AND RETAINER.
NOTE
If the snap ring groove is obscured by the washer
preventing the retainer from tting, try the
following. Grind the end of the new pin, in
small amounts, until the retainer just ts into
the groove.
RE-USE
Washer Retainer
Remove
Original
Lock-Up
Valve
Assembly
Slug
Valve
Pin
Installation (Input Shaft) Installation (Valve Body)
1.
Remove and discard the converter regulator
valve, spring, and isolator valve. Save the end
plug and clip.
Type 1
Type 2
Type 3
REMOVE AND DISCARD
2.
Install plain spacer spring and Iso-Conv valve.
The new Iso-Conv Valve replaces all 0.442 in.
diameter Iso-Conv valves.
Check you valve’s diameter. This valve does
not t oversized valve bores. Your original
valve must be 0.442 in. diameter.
0.440 in.
Re-Use
New ISO_CONV Valve Spacer