User Manual

12
JREMO 4L
Industrial radio remote controller
CHAPTER 3. INSTALLATION & FUNCTION SETTING
3-3-2. INSTALLATION SEQUENCE
A. Power o󽗈 equipment(ex. crane).
B. To install receiver always try to use with the Rx Fixing Plate or Rx Fixing
Bracket when applicable.
C. Connect each wire end of receiver cable to a mating connector of equip-
ment(ex. winch).
1. Con󽗉rm both circuit diagram of receiver and equipment(ex. winch) are
in sequence and connected correctly.
2. Con󽗉rm ground is o.k.
3. Check and con󽗉rm power source.
4. Make sure the selector switch positioned to pendent if pendent is (to
be) installed together with JREMO 4L.
D. Power on transmitter :
1. Twist up the EMS button.
2. Press Start Pushbutton of the transmitter and,
3. Con󽗉rm if the receiver MAIN Lamp is on.
E. Make sure each rx connection wires are temporarily disconnected to
equipment either by on-o󽗈 s/w or other means and then press each
function button of transmitter and con󽗉rm remote operation in a good
working condition by con󽗉rming to see each relay-led light inside the
relay board of receiver.
F. Close upper case of receiver and set the selector switch to remote posi-
tion if selector s/w is installed.
3-4 HOW TO START & USE PASSWORD(PWD)
For the safety and secure operation JREMO series has adopted several
types of start functions as following to achieve enhanced safety :
■ Main ON Function
Std : EMS UP ⇨ Any button, Main ON
Opt. : EMS UP ⇨ Start P/B, Main ON