Third Party Verification Claim
Test Report
Number:
SHAH01476379
Tests Conducted
Page 5 of 17
INTERTEK TESTING SERVICES LTD.
ZHEJIANG
浙江天祥质量技术服务有限公司
Building No.2, Juanhu Science and Technology
Innovation Park, No. 500 East Shuiyueting Road,
Haining City, Zhejiang Province,China. 314400
中国浙江省海宁市水月亭东路 500 号鹃湖科技创新
园 2 幢 314400
Tel: +86 573 87137200
Zip:314400
www.intertek.com
www.intertek.com.cn
Clause Test item Verdict
impact) onto the surface, so that it takes the entire weight without any support from the cycling
device.
Repeat for a total of 5,000 cycles.
There shall be no loss of serviceability to the unit.
13
Concentrated load test
This test is applicable for all tables.
Functional load test:
a) Apply the specified 90.7 Kg (200 lb.) Concentrated load to the primary surface through a 305
mm (12 in.) diameter disk so that its center is 178 mm (7 in.) from the unit’s edge at its
apparent weakest point.
b) When testing units with lengths (or diameters) greater than 1829 mm (72 in.), two 90.7 Kg (200
lb.) loads are required. The loads are applied through 305 mm (12 in.) diameter disks. The
centers of these disks shall be placed 915 mm ± 25 mm (36 in. ± 1.0 in.) apart and 178 mm (7
in.) in from the edge of the primary surface at the apparent weakest point.
c) Test time is 60 minutes.
There shall be no loss of serviceability.
Proof load test:
a) For tables with an area greater than 0.46 m
2
(5 ft.
2
), unless stated otherwise, the setup shall be
performed per Section 13 but with the appropriate 136.1 Kg (300 lb.) concentrated load(s).
b) For tables with an area equal to or less than 0.46 m
2
(5 ft.
2
), the setup shall be performed per
Section 13, except the 136.1 Kg (300 lb.) concentrated load shall be placed in the center of the
table.
c) Test to be performed for 15 minutes.
There shall be no sudden and major change in the structural integrity of the product. Loss of
serviceability is acceptable.
NA
14
Distributed Load Test
This test is applicable for all tables.
Functional load test:
A load of 1.5 lb./in. of perimeter shall be evenly distributed and centered over a line 203 mm (8 in.) in
from the edge along the entire perimeter.
Test to be performed for 60 minutes.
There shall be no loss of serviceability.
Proof load test:
Perform the setup per 14.1, Normal (Functional) load test, using a 2.3 lb./in of perimeter distributed
abnormal (proof) loads.
Test to be performed for 15 minutes.
There shall be no sudden and major change in the structural integrity of the product. Loss of
serviceability is acceptable.
NA
15
Table Unit Drop Test
This test is applicable only to tables with a weight of less than 136.1 Kg (300 lb.).
The unit shall be placed on a test platform.
Raise one end of the long axis of the unloaded unit so that the bottom of the base is 180 mm (7.1
in.) above the test platform or at the balance point, whichever is lower. The end of the unit being
tested shall be released and allowed a free fall to the test platform. Repeat for the other end of the
table unit.
There shall be no loss of serviceability.
NA
16
Leg Strength Test
This test is applicable for all tables.
Functional:
NA