2.4 To Measure Length of a Cable
Connect cable to main unit. A remote may be at the other end, but is
not required.
Turn on unit by pressing CABLE button. Press CABLE button until
Cable Length is displayed, then press SEL button. To change length
units between feet and meters, use setup mode.
Press up/down arrows to adjust length constant. If length constant
is unknown for a particular cable, a known length of cable may be
used to set the constant. Fifty feet or more is suggested to minimize
the resolution error (1 foot in 50 is 2% uncertainty). Connect known
cable to tester and change the cable constant using up/down arrows
until the length reads correctly.
2.5 To Locate an Ethernet Port
With LanScaper™ powered off, connect LanScaper™ to a jack or
plug at the workstation location for which the Ethernet port is to be
located.
Press NTWRK button, LanScaper™ will power up in the Flash
Link LED mode and connect to the Ethernet port on a HUB, switch
or NIC. Even if no connection is made, tone is generated on the
cable to aid in nding the cable with a tone tracer at the other end
(equipment closet).
If an Ethernet link is active on the cable the LanScaper™ turns on
its link LED and begins ashing it in unison with the link indicator
on a port of the HUB, switch or NIC at the other end. Tone is also
generated on the cable in this condition, but at a different cadence to
indicate having established a link.
2.6 To PING Devices on a Network
If the jack or plug is unknown, run Jack ID test rst. The PING function
operates in two modes DHCP On and Off (Manual). This is selected
in SETUP by the DHCP On/Off option. No other entries are required to
establish communications with a router and a DNS server on a DHCP
network. To PING a specic target (Tg1-4), the address must be entered
and the desired target address selected in SETUP before starting the
PING test. In DHCP Off mode, all IP conguration information must be
entered in SETUP rst.(PING Setup option)
With LanScaper™ powered off, connect to network.
Press NTWRK button repeatedly until PING Test is displayed on
screen (two presses when off). Press SEL button to enter test.
Several status screens will be displayed while establishing a link and
negotiating the DHCP conguration. Once PINGing begins, a PING
status screen will be displayed, showing acronyms for each active
conversation.
1)
2)
3)
1)
2)
3)
1)
2)