Installation Instructions

COD. 1248034-GB / 1.1
RBAND/OS – RBAND/OSB
- 3 -
The activation time of the opto safety edge can be modified. Before doing this operation it is necessary to know the door
travel time.
1. Press the receiver PROG and CHECK buttons simultaneously until the three CHECK, B1 and B2 leds go light on.
2. Press the PROG button to begin the memorisation of the time the opto safety edge will be activated. You will hear a
beep each second, to count the time easier.
3. Press the PROG button another time to memorise the total time the opto safety edge will be activated.
4. Program the transmitter to the receiver again (see paragraph PROGRAMMING).
CONNECTION OF THE VOLTAGE FREE CONTACT
When a voltage free contact is to be connected, (eg. photocells or electromechanical safety edges without resistive output),
fit the jumper in CS position.
Note: In order to comply with the EN 12453 safety standard for the use of motorized garage doors, the device connected
to this input must have some verification system to ensure its proper functioning.