User's Manual

www.milleredge.com info@milleredge.com 800-220-3343
IMAGE 2. RBAND GATE EDGE RECEIVER PCB & CONNECTIONS
LED INDICATORS
Initial Power
No Transmitters Programmed:
R1 & R2 LEDs on
R1 or R2 LED
Programmed: Off
Fault Condition: On
R3 LED
On when battery is low
A TEST LED
On when in test mode
CHECK LED
(both channels programed)
Programmed: Check LED flashes every
5 seconds
DIP SWITCH SETTINGS
ON
1 2 3 4
Switch 1-3: Leave switches in factory
default settings
Switch 4: Used to enable Normally Closed
cycle testing:
N.C. Operator: Set to on and connect
the switched power to the A Test and
Common pins shown above
10K Operator: Set to off
TABLE 1.
REMOVABLE CONNECTORS
For Normally Closed gate operators,
please reference page 5.
8-PIN CONNECTOR
Power
+12/24 AC/DC Constant power source
-12/24 AC/DC Constant power source (ground)
Relay Output 1
CS1 N.C. monitored input
C1 Monitored input Common
BS1 10K monitored input
Relay Output 2
CS2 N.C. monitored input
C2 Monitored input Common
BS2 10K monitored input
4-PIN CONNECTOR
Relay Output 3
NO3 Low battery alarm (optional)
C3 Low battery alarm (optional)
N.C. Power Cycling
COM. COM: Switched power Common
A TEST +12/24VDC: Switched power
source
GND ANT
R2
R1
R3 A TEST
CHECK
PROG
ON
1
2
3
4
12/24 AC/DC
CS1 C1
+ -
BS1 CS2 C2 BS2 NO3 C3
COM.
A TEST
MR
PROGRAM
BUTTON
CHECK LED
& BUTTON
REMO
VABLE
8-PIN CONNECTOR
DIP SWITCHES
RELAY
LEDS
ANTENNA
TERMINAL
BLOCK
REMOVABLE
4-PIN CONNECTOR
COAXIAL CABLE
PROVIDED BY
INSTALLER
ANTENNA
F-CONNECTOR
COAX EXTENDER