Installation Guide
www.milleredge.com info@milleredge.com 800-220-3343
IMAGE 2. RBAND GATE EDGE RECEIVER PCB & CONNECTIONS
LED INDICATORS
Initial Power
• No Transmitters Programmed:
R1 & R2 LEDs on
R1 or R2 LED
• Programmed: Off
• Fault Condition: On
R3 LED
• On when battery is low
A TEST LED
• On in test mode
CHECK LED
(both channels programed)
• Programmed: Check LED flashes every 5
seconds
DIP SWITCH SETTINGS
ON
1 2 3 4
Switch 1-4: Leave switches in factory default
settings
TABLE 1.
REMOVABLE CONNECTORS
8-PIN CONNECTOR
Power
+12/24 AC/DC Constant power source
-12/24 AC/DC Constant power source (ground)
Relay Output 1
CS1 Not used
C1 10K monitored input common
BS1 10K monitored input
Relay Output 2
CS2 Not used
C2 Not used
BS2 Not used
4-PIN CONNECTOR
Relay Output 3
NO3 Low battery alarm (optional)
C3 Low battery alarm (optional)
N.C. Power Cycling
COM. Not used
A TEST Not used
GND ANT
R2
R1
R3 A TEST
CHECK
PROG
ON
1 2 3
4
MR
12/24 AC/DC
CS1 C1
+ -
BS1 CS2 C2 BS2 NO3 C3
COM.
A TEST
ANTENNA
PROGRAM
BUTTON
CHECK LED
& BUTTON
REMOVABLE
8-PIN CONNECTOR
DIP SWITCHES
RELAY
LEDS
ANTENNA
TERMINAL
BLOCK
REMOVABLE