User's Manual

RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 19
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
3. AUTO-TEST FUNCTION
3.1 AUTO-TEST DESCRIPTION
Before starting operations, the control panel must check that the entire security
system is working correctly. The control panel shall not start Auto-test during a
pressed safety edge output.
To make this check, the panel must act on the auto-test signal.
AUTO-TEST timing correct
AUTO-TEST timing error
While the auto-test is being run to learn of the status of the RADIOBAND/TA or
RADIOBAND/TBX, the RADIOBAND/RU questions the status of the different Safety
edges inputs. This process ensures the correct working order of the following
parts:
Safety edge input
RADIOBAND/TA or RADIOBAND/TBX (1 or several).
RF Channel (if there is any interference)
Autotest
CS
= indicates
the correct
autotest of all
b
ands
RADIOBAND/TA status
Auto-test carried out
Autotest OK
T
autotest
T
end
The operation can now be
carried out
Autotest
RADIOBAND/TA status
Auto-test carried out
Autotest Error
T
MAXautotest
T
end
THE OPERATION CANNOT BE STARED AS
THE AUTO-TEST HAS NOT BEEN
SUCCESSFULLY COMPLETED
CS
= indicates
the correct
autotest of all
b
ands