User's Manual
COD. 1248017-GB / 1.2
BASE500
3
TOTAL RESET
In programming mode, the programming button is held down and the “MR” reset jumper
is bridged for 3 secs. The receiver will issue 10 short acoustic warning signals followed by
others at a faster pace to indicate that the operation has been successful. The receiver is
now in programming mode.
After 10 seconds without programming or quickly pressing the programming button, the
receiver will exit programming mode, issuing two acoustic signals of 1 sec.
GROUPS
Receivers can be configured with a group (from 0 to 7) so that there is no interference
when working near each other.
125kHz
125kHz 868MHz
125kHz
C3- G1
C2- G2
C3- G1
G1
G2
125kHz 868MHz
C2- G1
C2- G1
C3- G2
C2- G2
C3- G2
C1- G0
C2- G0
C=channel
G=group
N.B. Group 0 enables all groups.
GROUP CONFIGURATION
The configuration can be carried out with the programming tool or by self-programming as
follows.