Instruction Manual
Installation instructions for JC110001 Emergency Bulkhead
Emergency Range
company
a
Important warranty information
This product is supported by a 2-year standard warranty which will extend to 5 years if registered within the first year of purc
hase.
(5 year on batteries). Please register at jcc.co.uk/warranty - Terms and conditions apply.
The installer will be asked to provide the following information, which is detailed on a label attached to the luminaire’s chas
sis:
Product Code/Date Code.
JCC Lighting Products Ltd. Innovation Centre, Beeding Close, Southern Cross Trading Estate, Bognor Regis, West Sussex, PO22 9TS, United Kingdom
Technical Support: +44(0)1243 838986 Customer Services: +44(0)1243 838999
BS EN ISO9001 - 2015 - Registered Firm Certificate No. GB 1552
V4_August_2021_RS
Warnings & Cautions
• To avoid electric shock, serious injury or property damage,
isolate power before installing, removing or servicing the product.
• It is recommended that luminaires are installed by a qualied
electrician to ensure the installation complies with the local current
wiring regulations.
• It may be necessary to upgrade your MCBs to allow for increased
inrush current.
• This product is designed for connection to a 100-240V~ 50/60Hz.
• It is recommended that the ambient room temperature should not
exceed 26°C.
• All testing should be carried out in accordance to EN 50172:2004
• The light source of this luminaire is not replaceable: when the light source
reaches the end of its life the whole of the luminaire must be replaced.
• Read instructions and check that you have all of the tools and
accessories required to complete the installation correctly.
Isolate power supply before starting installation.
• Do not carry out insulation tests with the product connected to
the circuit.
• Any broken or damaged parts should be replaced as soon as possible.
JCC will not accept responsibility for claims arising from sub-standard
installations; which will void the warranty.
• This luminaire is suitable for indoor and outdoor use.
INSTALLATION
ENGLISH
RoHS
Compliant
IP65 jcc.co.uk
Colour temp: 7000K Ra: 84
Wire preparation: 1-2.5
mm²
3W 100-240V~ 50/60Hz - Class II
Supplied legends:
1 x left running man, 1 x right running man, 1 x directional arrow
Prole & Dimensions
All dimensions in millimetres
Non-replaceable control gear
Non-replaceable light source
LED
LED
352
68
110
Light source: Integral LED
Wattage:3W
Lumens: 120 lumens
KEY:
E: EARTH PROVISION
N: NEUTRAL
L: U/SWITCHED LIVE(in)
L1: U/SWITCHED LIVE(out)
L2:Sw/LIVE
Neutral: Blue
U/sw Live(in): Black
U/sw Live: (out)Black
E(provision only)
Sw/Live: Brown
N
L
L1
E
L2
Maintained(3M)
+ on/off Switched
+ Emergency
Neutral: Blue
U/sw Live(in): Black
U/sw Live(out): Black
E(provision only)
Sw/Live: Brown
N
L
L1
E
L2
Maintained(3M)
+ Light on 24/7
+ Emergency
(linked)
Neutral: Blue
U/sw Live(in): Black
U/sw Live:(out) Black
E(provision only)
Sw/Live: (do not use)
N
L
L1
E
L2
Non-Maintained(3NM)
+ Light off 24/7
+ Emergency
(remove link)
1. Remove the two screws holding the diffuser to gain access to the
interior.
2. Release the LED tray to access the mains input terminal by pressing
the quick release tabs. This is hinged so the LED tray remains attached
to the body.
3. Cable entry is available through rear, top and bottom or both ends.
Ensure appropriate grommets or compression couplings are used to
maintain the IP65 rating where required.
4. Connect the mains input supply as indicated on the above as per the
required operation.
5. Connect the emergency battery leads to the circuit board where
indicated.
6. Close the LED tray, ensuring it is secured using the securing tabs.
7. Ret the diffuser ensuring there is a good seal to maintain the IP65
rating.
8. Switch on mains supply and test for operation(allow 24hrs for batteries
to charge). Charging and normal operation is indicated when the green
light is on
9. Fit the legends on the front of the diffuser to suit the application from
the three choices indicated on the right which are included.
10. Familiarise yourself with the enclosed emergency ttings test record
sheet and ensure it is completed as required and left with the end user.
479.5
95.7
191.4 191.4 96.2