OPERATOR'S MANUAL MAINTENANCE

Table Of Contents
Section C - Electrics
Basic System Operation
Pump Control for Each Mode
C-22 C-22
9803/9880-3
Pump Control for Each Mode
Operation
Fig 23.
The machine can operate in four different modes,
depending upon the type of work required
K Engine
Throttle Control ( T C-18). The pump output horsepower
is varied by means of a PWM signal to the pump control
solenoid valve which varies for each mode.
Tier III machines are required to reduce the "range band"
"X to Y" (pump milliamps)
K Fig 25. ( T C-24), to improve
engine stability dependant on specific factors which
include:
Barometric Pressure
Fuel Temperature
Air Intake Temperature
Air Conditioning
Engine and Hydraulic Temperature
These conditions are monitored by ECU1. Engine power
and pump power are then varied to suit the operating
conditions.
Each of the above factors has a value calculated by ECU1
of between 0 and 1. All values are then calculated to give
a dynamic control factor (DCF) of 0 to 1 which will
determine the pump output power and will vary the pump
mA to suit.