OPERATOR'S MANUAL MAINTENANCE

Table Of Contents
Section E - Hydraulics
Solenoid Valve (8 Station)
Dismantling and Assembly
E-119 E-119
9803/9880-3
Dismantling and Assembly
T023430
Fig 2.
Dismantling
1 Unscrew cap A from solenoid valve.
2 Slide solenoid B, away from the main control valve.
3 Loosen spool C and extract spool from the main
control valve.
4 Repeat steps 1-3 to remove all solenoid valves from
the valve.
5 Remove plug D and extract spring E and ball F.
6 Unscrew accumulator G and remove from valve.
7 Remove hex pug H.
8 Using a 5mm Allen key remove valve J, ball K and
seat L.
Inspection
Before assembling the solenoid valve make sure that a
thorough inspection of all the components is carried out.
Remember that although a failed component may be easy
to identify, the cause may be less easy to trace. It is also
possible that a failed component may have caused
damage to other areas of the valve.
1 Carefully clean all components using a suitable
degreasing agent.
2 Carefully inspect all components for signs of
excessive wear or damage. If wear or damage is
evident, components must be renewed.
E
D
F
C
B
A
H
J
K
G
L