Quick Guide for Beginners
CBT Quick Start Guide
17 
Example #4 –Three-Tiered Raked, Large Room 
Description –This is a larger room with a depth of 39.6 m (130 ft). The room could represent a venue 
with dual balcony or it could represent an auditorium with a front section having a gentle rake and 
a back having a steeper rake. Shown are the CBT 100LA, CBT 70J and the CBT 70J+70JE 
combination. All are set at the Broad Vertical Coverage setting. 
Listening Plane = Three tiers 
Mic Placement = 7.6 m (25 ft, red icon) and 19.8 m (65 ft, blue icon) on main seating; 22.9 m (75 ft, 
green icon) and 32 m (105 ft, pink icon) on middle seating plane; the rear of the back seating plane 
at 38.1 m (125 ft, light-blue icon). 
CBT 100LA in Broad Setting 
Trim Height = 4.3 m (14 ft, Top of Speaker) 
Down Tilt = 5° 
Vertical Coverage Setting = Broad 
SPL
(Full rated power, low-Z, SPEECH setting, 4 kHz, scale in feet): 
0
20
40
60
0 40 80 120 160
105
100
95
90
85
80
75
Frequency Response (Full rated power, low-Z, speech setting, mic positions as designated above): 
SPL Range 
4 kHz