Instructions
Notes
Specifications
CS-1F 120V 50/60Hz. Input fuse: 2A. Output: 23.5V. Control Unit model: CSV-1F
CS-2F 230V 50/60Hz. Input fuse: 1A. Output: 23.5V. Control Unit model: CSV-2F
CS-9F 100V 50/60Hz. Input fuse: 2A. Output: 23.5V. Control Unit model: CSV-9F
- Output Peak Power CS-F: 40W
- Temperature Range: 180 - 450 °C / 360 - 840 °F
- Idle Temp. Stability (still air): ±1.5ºC / ±3ºF (Meets and exceed IPC J-STD-001)
- Temp accuracy: ±3% (using reference cartridge)
- Temp adjustment: ±50ºC / ±90ºF Through station menu setting
- Tip to ground voltage/resistance: Meets and exceed
ANSI/ESD S20.20-2014 IPC J-STD-001F
- Earthing Fuse: F 1.25A
- Connections: USB connector station-PC
RJ12 Connector
- Ambient operating temp: 10 - 50 ºC / 50 - 122 ºF
- Control Unit Dimensions / Weight: 170 x 176 x 145 mm / 2.8 Kg
(L x W x H) 6.7 x 6.9 x 5.7 in / 6.17 lb
MS-A
- Dimensions / Weight: 145 x 55 x 225 mm / 1.2 kg
(L x W x H) 5.7 x 2.2 x 8.9 in / 2.6 lb
- Vacuum: 75% / 570 mmHg / 22.4 inHg
- Flow rate: 9 SLPM
- Total Package Dimensions / Weight: 495 x 295 x 255 mm / 5.47 kg
(L x W x H) 19.5 x 11.6 x 10 in / 12.06 lb
Complies with CE standards.
ESD protected housing.
www.jbctools.com
23