User's Manual

UDEE / UDRE - 332170A revision02 - 33 -FrEnDePRELIMINARY
Housing
ABS, Grey - IP65
Weight
2 kg (approx.)
Dimensions
160x250x120 mm (without antenna and cable gland)
Operating temperature range
- 20°C to + 50°C
Storage temperature range
- 30°C to + 70°C
Cable lead-outs
Power supply : 1 M16 caps (Ø 5 to 7 mm cables)
Control outputs : 1 M32 plastic cable gland (Ø 20 to 26 mm cables )
Connection
Spring-type terminal strips for 0.08² to 2.5² section wires
64 programmable UHF channels in 911-918 MHz bands
ref:
VUB984
, 1/2 wave in 911-918MHz
Sensitivity
< -100dBm
AC version
115VAC, -15% to +10%, 180mA
230VAC, -15% to +10%, 85mA
Control
1 "Horn" relay and 18 function relays
Safety
2 safety relays with linked and guided contacts
Response time
On start-up : 0,5s max.
On control : 55 ms max.
Active shutdown time
145 ms max.
Passive shutdown time
1,1 s max.
Indicator lights
1 red indicator light "power on"
1 red + 1 green indicator lights for diagnostic
1 red indicator light for relay status
Protections
Power supply :
Against overcurrents by fuse
Reception frequency
(see list in appendix)
Mechanical and environment withstand characteristics
Radio characteristics
Electrical characteristics
Characteristics complying with FCC part 15
Antenna
(BNC plug-in type)
Power supply and consumption
(1)
(with 2 saf ety relays and 8 control
relays pulled in)
5.4-
UDRE UDRE
UDRE UDRE
UDRE receiver technical characteristics
A large label in the housing cover gives the following information to facilitate configuration and
maintenance of the UDEE/UDRE system :
- connection point numbers
- wiring indication
- fuse characteristics
- indicator light functions
- table showing the "Buttons/Relays/Functions" configurations for the application and the
interlocking configuration.
(1) = The number of function relays controlled simultaneously is limited to 10 relays connected to
UDRE receiver..