User's Manual
Table Of Contents
Command Line Interface
Diagnostics and Identification Commands
STATE
31www.javad.com
Product ID = 6
S/N = 000000 020303
Hardware = Ver. 1.0
Software = Ver. 1.0 Rev. B
BootLoader = Ver. 1.0 Rev. A
Figure 3-2. INFO Command Display
3.5.2. STATE
The STATE command is used to check the state of the wireless link, the unit in the link, and the
alarm control lines. To specify a radio unit (local or remote), the CONNECT command must be
used in prior of STATE command using.
STATE [Parameter Name] [Parameters List] [/?]
Note: The indicated receive signal strength (RSSI) is equal to -147 dBm if there is no signal received
from transmitter.
Parameter Name Parameter List
TTL1 0/1 – State of TTL_IN1 line
TTL2 0/1 – State of TTL_IN2 line
RSSI -52 to -116 dBm – Indicates the Receive Signal Strength in dBm
BER 1.0E-6 to 9.9E-3 – Indicates the BER level
FREQ 403.000000 to 470.000000 MHz – Displays the central frequency of the operating
channel
CHAN 1 to 9601 – Displays the selected or currently scanned frequency channel
TEMP -30°C to 100°C – Displays the temperature inside of enclosure
SYNC 1 – Indicates the established link, 0 – if link is not established yet
PWRB Indicates unit’s output power level in dBm (see “CONNECT” on page 24)