SDS
03/02/2021Revision:
Page: 3 of 9
JASCO PREMIUM PAINT & EPOXY
REMOVER
SAFETY DATA SHEET
08/06/2018Supersedes Revision:
5. FIRE FIGHTING MEASURES
Flash Pt:
Fire Fighting Instructions:
Flammable Properties and
Hazards:
Autoignition Pt:
Explosive Limits:
Suitable Extinguishing Media:
Unsuitable Extinguishing
Media:
Hazardous Combustion
Products:
74.00 F Method Used: Setaflash Closed Cup (Rapid Setaflash)
Self-contained respiratory protection should be provided for fire fighters fighting fires in
buildings or confined areas. Storage containers exposed to fire should be kept cool with
water spray to prevent pressure build-up. Stay away from heads of containers that have
been exposed to intense heat or flame.
Danger! Flammable. Keep away from heat, sparks, flame, and all other sources of
ignition. Do not smoke. Extinguish all flames and pilot lights, and turn off stoves,
heaters, electric motors and all other sources of ignition during use and until all vapors
are gone. Beware of static electricity that may be generated by synthetic clothing and
other sources.
N.D.
LEL: N.D. UEL: N.D.
Flammability Classification 1C
Use carbon dioxide, dry powder, or alcohol resistant foam.
Do not use straight streams of water. If water is used, use a water spray or fog.
Carbon monoxide, carbon dioxide. sulfur oxides, hydrogen sulfide
6. ACCIDENTAL RELEASE MEASURES
Steps To Be Taken In Case
Material Is Released Or
Spilled:
Vapors may cause flash fire or ignite explosively.
Clean up: Keep unnecessary people away; isolate hazard area and deny entry. Stay
upwind, out of low areas, and ventilate closed spaces before entering. Shut off ignition
sources; keep flares, smoking or flames out of hazard area. Use non-sparking tools.
Use proper bonding and grounding methods for all equipment and processes. Keep out
of waterways and bodies of water. Be cautious of vapors collecting in small enclosed
spaces, sewers, low lying areas, confined spaces, etc.
Small spills: Take up with sand, earth or other noncombustible absorbent material and
place in a plastic container where applicable.
Large spills: Dike far ahead of spill for later disposal.
Waste Disposal: Dispose in accordance with applicable local, state and federal
regulations.
7. HANDLING AND STORAGE
Precautions To Be Taken in
Handling:
Read carefully all cautions and directions on product label before use. Since empty
container retains residue, follow all label warnings even after container is empty.
Dispose of empty container according to all regulations. Do not reuse this container.
Do not use this product near any source of heat or open flame, furnace areas, pilot
lights, stoves, etc.
Do not use in small enclosed spaces, such as basements and bathrooms. Vapors can
accumulate and explode if ignited.
Licensed to W.M. Barr and Company
GHS format