CONNECT RANGE TO GAS SUPPLY 
• When all connections have been made, check 
that all range controls are in the ‘OFF’ position 
and open the main gas supply valve. 
• Leak testing of the appliance shall be 
conducted according to the manufacturer’s 
instructions. Use some soapy water (50% water 
and 50% liquid detergent) or a leak detector at all 
joints and connections to check for leaks in the 
system. Open the valve and check for leaks by 
placing the liquid solution onto all gas 
connections. Bubbles around connections 
indicate a gas leak. If a leak appears, close the 
shut-off valve, and adjust connections. Do not 
use a flame to check for gas leaks. 
• The appliance must be isolated from the 
building’s gas supply piping system by closing 
its individual manual shut-off valve during any 
pressure testing of the gas supply piping system 
at test pressure equal to or less than ½ psi 
(3.5kPa). 
Gas shut-off valve
IMPORTANT: The range must be connected to a regulated gas supply. The supply 
line must be equipped with an approved external gas shut-off valve located near the 
range in an accessible location. Do not block access to the shut-off valve. 
• All connections to the gas piping must be wrench-tightened. Do not overtighten or 
allow pipes to turn when tightening. 
• Any pipe connections must be made using a thread sealant approved for gas 
connections. Failure to correctly install these items could lead to a gas leak and 
subsequent explosion. 
• Install male ½” flare union adapter to ½” NPT internal thread elbow at inlet of 
regulator. On models equipped with standard double burners, install the male pipe 
thread end of the ½” flare union adapter to the ½” NPT internal thread at inlet of 
pressure regulator. Use a wrench on the regulator fitting to avoid damage. 
• Install male ½” or ¾” flare union adapter to the NPT internal thread of the manual 
shut-off valve, taking care to secure the shut-off valve to keep it from turning. 
• The gas supply pressure for checking the regulator setting is 7” (Natural Gas) and 
11” (LP gas).  Connect  flexible  gas  line  connector  to  the  regulator  on  the  range. 
Position range to permit connection at the shut-off valve.