Full Product Manual

CONNECT RANGE TO GAS SUPPLY
When all connections have been made, check
that all range controls are in the ‘OFF’ position
and open the main gas supply valve.
Leak testing of the appliance shall be
conducted according to the manufacturer’s
instructions. Use some soapy water (50% water
and 50% liquid detergent) or a leak detector at all
joints and connections to check for leaks in the
system. Open the valve and check for leaks by
placing the liquid solution onto all gas
connections. Bubbles around connections
indicate a gas leak. If a leak appears, close the
shut-off valve, and adjust connections. Do not
use a flame to check for gas leaks.
The appliance must be isolated from the
building’s gas supply piping system by closing
its individual manual shut-off valve during any
pressure testing of the gas supply piping system
at test pressure equal to or less than ½ psi
(3.5kPa).
Gas shut-off valve
IMPORTANT: The range must be connected to a regulated gas supply. The supply
line must be equipped with an approved external gas shut-off valve located near the
range in an accessible location. Do not block access to the shut-off valve.
All connections to the gas piping must be wrench-tightened. Do not overtighten or
allow pipes to turn when tightening.
Any pipe connections must be made using a thread sealant approved for gas
connections. Failure to correctly install these items could lead to a gas leak and
subsequent explosion.
Install male ½” flare union adapter to ½” NPT internal thread elbow at inlet of
regulator. On models equipped with standard double burners, install the male pipe
thread end of the ½” flare union adapter to the ½” NPT internal thread at inlet of
pressure regulator. Use a wrench on the regulator fitting to avoid damage.
Install male ½” or ¾” flare union adapter to the NPT internal thread of the manual
shut-off valve, taking care to secure the shut-off valve to keep it from turning.
The gas supply pressure for checking the regulator setting is 7” (Natural Gas) and
11” (LP gas). Connect flexible gas line connector to the regulator on the range.
Position range to permit connection at the shut-off valve.
17