GAS SUPPLY REQUIREMENTS 
• Installation and service must be performed by a qualified installer. 
• The range has been equipped and adjusted for use with natural gas (NG) at manu-
facture. 
• For use with liquid propane (LP) gas, the range must be properly adjusted by a qual-
ified installer. The appliance has been supplied with a liquid propane (LP) Conversion 
Kit. Each orifice has been clearly identified on the orifice packaging to identify with 
which burner it corresponds with. Refer to the ‘PARTS’ section of this manual for a 
table listing orifice sizing. 
• Ensure the gas appliance pressure regulator has been set for the gas which the 
appliance will use. The gas appliance pressure regulator is located at the bottom 
right, rear of the range. 
• Installation of this range must conform with local codes, or in the absence of local 
codes, the National Fuel Gas Code, ANSI Z223.1 / NFPA 54. This range has been 
design-certified  according  to  CSA/ANSI  Z21.1/CSA  1.1:2018  Ed.2+E2019  latest 
edition. 
• A statement of the maximum gas supply pressure in accordance with the inlet pres-
sure rating of the gas appliance pressure regulator supplied. 
MINIMUM GAS SUPPLY PRESSURE TO APPLIANCE FOR NATURAL GAS (NG) – 7.0 
IN.W.C. 
MINIMUM GAS SUPPLY PRESSURE TO APPLIANCE FOR LIQUID PROPANE GAS (LP) 
- 11.0 IN.W.C. 
APPLIANCE REGULATOR IS SET AT 5.0 IN. W.C. OUTLET PRESSURE. 
16